30 JUNE 2026

Water, Waste and Toilets: The Unglamorous Systems That Make or Break Your NSW Glamping Site

No one books a glamping trip for the sewage system. But water, waste, and toilets are the systems that determine whether your NSW glamping site stays open โ€” or gets shut down. Here's what you need to know.

By Jesse Anyan

Founder of Glamporise

TL;DR

Every NSW glamping site needs three things sorted before guests arrive: safe drinking water, a compliant waste system, and enough water on hand for firefighting. Whether you go traditional (septic, mains connection) or eco-friendly (composting toilets, greywater reuse), the same rule applies โ€” Section 68 approval from your local council is required before you install or operate most water and waste systems. Get these right and your guests never think about them. Get them wrong and you’ll hear about it fast.

Nobody Books a Glamping Trip for the Plumbing

But they will absolutely leave a one-star review because of it.

Water and waste are the invisible infrastructure of a glamping site. When they work, guests don’t notice. When they don’t โ€” blocked composting toilet, no hot water, dodgy drainage smell near the deck โ€” it’s the only thing they remember.

Beyond the guest experience, water and waste systems are also one of the most closely scrutinised compliance areas for rural accommodation in NSW. Councils care about what goes into the ground and what comes out of your taps. And they have the tools to check.

This blog covers the systems you need, the options available, and what compliance looks like for each โ€” so you can design a site that works for your guests, your council, and the land itself.

Follow Us:

More Posts

Subscribe to our Newsletter:

Why Water Planning Is Non-Negotiable

Safe drinking water, reliable showers, and a dedicated firefighting supply are baseline requirements for any NSW glamping operation. NSW Health is clear on drinking water standards โ€” and councils enforce them.

Your Water Supply Options

Rainwater harvesting is the most common approach for off-grid and semi-off-grid glamping sites. Tanks collect roof runoff, which is then filtered and treated for drinking. The key requirements: appropriate tank capacity for your guest numbers, a filtration and treatment system that meets drinking water standards, and a separate dedicated tank for firefighting with a Storz fitting for fire truck connection.

Bores and groundwater are an option on properties with suitable aquifers. Water quality testing is essential โ€” groundwater quality varies significantly across NSW โ€” and extraction may require a licence from WaterNSW depending on volume.

Mains connection is available on some rural properties close to council infrastructure. Reliable but involves connecting to the council system, which requires Section 68 approval and ongoing usage charges.

The firefighting supply requirement applies regardless of which water source you use. On bushfire-prone land, a separate dedicated tank is not optional. Size requirements depend on your BAL rating and the number of structures on site โ€” a bushfire consultant or your council can advise on the specific volume required for your property.

What Requires Section 68 Approval for Water

As covered in the companion blog on Section 68, most water infrastructure on a glamping site triggers an additional council approval:

  • Connecting to or modifying council water supply
  • Installing or altering a water meter
  • Installing pumps connected to a bore or council supply
  • Carrying out stormwater drainage work

Check with your council before engaging a plumber. The Section 68 application for water infrastructure is typically straightforward โ€” but it needs to be lodged and approved before installation begins.

Sewage and Waste: Your Options and What Each Requires

This is the section most glamping operators underestimate. There are three main system types, each with different compliance requirements, costs, and maintenance demands.

Septic Systems

The traditional option. A septic tank collects and partially treats wastewater, which then disperses through absorption trenches or an aerated treatment unit.

Good for: Sites with suitable soil permeability, adequate setback distances from water bodies, and enough land for absorption areas.

Requirements: Soil testing before installation, Section 68 approval, installation by a licensed plumber, regular pumping (typically every 3โ€“5 years), and ongoing council inspection in some areas.

Watch out for: Minimum setback distances from waterways, bores, and property boundaries. These can significantly constrain your site layout if you haven’t factored them in early.

Composting Toilets

Waterless toilets that process waste into compost through aerobic decomposition. Excellent for remote sites, low water availability, or operators who genuinely want to minimise environmental footprint.

Good for: Sites where mains sewer connection isn’t available, water conservation is a priority, and the operator is committed to regular maintenance.

Requirements: Section 68 approval before installation. The composting toilet model must be approved for commercial use โ€” check the NSW Planning Portal’s waterless toilets guidance for compliant products. Guests need clear instructions (add carbon material after each use). Regular maintenance is non-negotiable: a neglected composting toilet is one of the most common sources of one-star reviews on eco-glamping sites.

Watch out for: Capacity. A composting toilet designed for residential use will not cope with commercial guest volumes. Size for your peak occupancy, not your average.

Cassette and Portable Toilets

Portable toilet systems where the waste is emptied at an approved disposal point. Work well for very small or low-occupancy sites, or as a transitional solution while permanent infrastructure is being approved.

Requirements: Waste must be disposed of at an approved disposal point โ€” not emptied on-site without proper management. Section 68 approval may still apply depending on the system and how it’s installed.

Greywater: The Rules Around Reuse

Greywater โ€” the wastewater from showers, sinks, and laundry โ€” can be reused for garden irrigation and is an attractive option for eco-conscious operators.

The rules: greywater reuse systems must comply with the NSW Planning Portal’s greywater guidelines and use WaterMark-certified products where applicable. Reed beds, subsurface irrigation, and purpose-built greywater treatment systems are all viable options โ€” but each needs to be designed for the volume of water your site produces and maintained regularly.

Key design considerations:

  • Choose native plants suited to greywater irrigation โ€” they tend to handle the nutrient load well and need less additional watering
  • Set buffer distances from vegetable gardens, waterways, and property boundaries
  • Install proper inspection access so the system can be serviced without excavation
  • Train staff on what can and can’t go down the drain โ€” cooking oils and harsh chemicals wreck biological treatment systems fast

Eco-Friendly Doesn't Mean Exempt From Compliance

This is worth saying plainly, because it catches a lot of operators who are trying to do the right thing by the environment.

Composting toilets, greywater gardens, and rainwater harvesting are all genuinely better for the land than traditional alternatives. But none of them bypass the Section 68 approval requirement. None of them exempt you from drinking water standards. And none of them replace the need for a properly designed and maintained system.

The councils that deal with rural accommodation issues most frequently are not anti-eco. They’re pro-evidence. Show them a properly designed system with a maintenance plan and a compliant product, and approval is usually quick. Show up with an uncertified composting toilet installed without approval, and you’ll have a problem regardless of how good your intentions were.

Practical Tips for Getting These Systems Right

Design water and waste into your site layout from day one. Setback distances for septic absorption areas, tank placement for firefighting access, and greywater irrigation zones all affect where your structures can go. Trying to fit these in after you’ve committed to a site layout is expensive and sometimes impossible.

Oversize your systems. The cost difference between a system designed for your average occupancy and one designed for your peak occupancy is small. The operational difference when you’re fully booked on a hot summer weekend is enormous.

Wildlife-proof your waste bins. This is in Jesse’s original draft and it’s worth keeping: birds, lizards, possums, and the full cast of Australian wildlife will absolutely get into unsecured bins. Invest in properly sealed containers from the start.

Build maintenance into your operating costs. Septic pumping, composting toilet servicing, greywater system checks โ€” these are recurring costs, not one-off installations. Budget for them as part of your annual operating expenses before you open.

Keep records. Councils may ask for evidence that your systems are being maintained properly. A simple maintenance log โ€” date, what was done, who did it โ€” is enough to demonstrate compliance if questions arise.

Your Next Step

Water, waste, and toilet systems are part of the detailed planning work that separates a glamping site that opens smoothly from one that gets delayed by compliance issues. The NSW Glamping Planning Pathway covers the full picture โ€” including infrastructure planning, approval requirements, and site design guidance across all four stages.

(See all four stages and find the one that fits your situation.)

Keep Reading

This is the first in a series of guides walking NSW landowners through the glamping planning process from start to finish. Next up:

Bushfire Basics for NSW Glamping Sites: BAL Ratings, Fire Safety and What Council Actually Expects

30 JUNE 2026 Bushfire Basics for NSW Glamping Sites: BAL Ratings, Fire Safety and What Council Actually Expects Bushfire planning isn’t optional for NSW glamping operators โ€” it shapes your site layout, your structures, and your approval pathway. Here’s what BAL ratings mean and what every glamping site needs to have in place. By Jesse Anyan Founder of Glamporise TL;DR Most rural NSW properties sit on bushfire-prone land. For glamping operators, that means a Bush Fire Attack Level (BAL) assessment is required as part of your planning and building approvals โ€” and your BAL rating determines everything from your setbacks

Read More โ†’

The Hidden Permits Most NSW Glamping Operators Miss: Section 68 Approvals Explained

30 JUNE 2026 The Hidden Permits Most NSW Glamping Operators Miss: Section 68 Approvals Explained You’ve got your DA sorted โ€” but did you know a separate council permit may be required before you install a composting toilet, a moveable dwelling, or a water tank? Here’s what Section 68 covers and why glamping operators keep getting caught out by it. By Jesse Anyan Founder of Glamporise TL;DR Section 68 of the Local Government Act 1993 requires a separate council approval for specific activities โ€” including installing moveable dwellings, setting up water and waste systems, and operating on-site sewage management. This

Read More โ†’

STRA vs Tourist and Visitor Accommodation: What NSW’s Short-Stay Rules Actually Mean for Glamping

30 JUNE 2026 STRA vs Tourist and Visitor Accommodation: What NSW’s Short-Stay Rules Actually Mean for Glamping Think your glamping domes need to register as STRA? They almost certainly don’t. Here’s the distinction NSW glamping operators need to understand โ€” and why getting it wrong costs you. By Jesse Anyan Founder of Glamporise TL;DR STRA (Short-Term Rental Accommodation) rules apply to residential dwellings โ€” spare rooms, holiday houses, apartments. Glamping domes, safari tents, yurts, and eco-tourist facilities are classified as tourist and visitor accommodation, which is an entirely different category. That means most glamping operators don’t need to register with

Read More โ†’